21 results

Buried Utilities Beneath a Reinforced Concrete Slab: Detection Through Dense Reinforcement
Underground UtilitiesConcrete / Civil Eng.

Buried Utilities Beneath a Reinforced Concrete Slab: Detection Through Dense Reinforcement

UtilityScan DF300/800 MHz
GPR Survey of a Car Park Raft Slab Showing Multiple Defects and Forms of Distress
Concrete / Civil Eng.Geotechnics

GPR Survey of a Car Park Raft Slab Showing Multiple Defects and Forms of Distress

NX151500 MHz
Industrial Slab GPR Survey: Heterogeneous Reinforcement and Subgrade, Inputs for Bearing Capacity Assessment
GeotechnicsConcrete / Civil Eng.Underground Utilities

Industrial Slab GPR Survey: Heterogeneous Reinforcement and Subgrade, Inputs for Bearing Capacity Assessment

UtilityScan DF300/800 MHz
Reinforced Concrete Accessibility Ramp: Three Frequencies, Two 2.5 GHz Antennas and Cross-Polarisation on the Same Profile
Concrete / Civil Eng.

Reinforced Concrete Accessibility Ramp: Three Frequencies, Two 2.5 GHz Antennas and Cross-Polarisation on the Same Profile

FLEX NX;NX25;UtilityScan DF300 à 2500 MHz
Circular Reinforced Concrete Column : Perimeter Scan and Rebar Repositioning in Section View
Concrete / Civil Eng.

Circular Reinforced Concrete Column : Perimeter Scan and Rebar Repositioning in Section View

FLEX NX2500 MHz
Reinforced Concrete Beam: Continuous Longitudinal GPR Survey with Markers at Two Columns
Concrete / Civil Eng.

Reinforced Concrete Beam: Continuous Longitudinal GPR Survey with Markers at Two Columns

FLEX NX2500 MHz
T-Shaped Retaining Wall: Variable Thickness from a Vertical then Horizontal GPR Profile
Concrete / Civil Eng.

T-Shaped Retaining Wall: Variable Thickness from a Vertical then Horizontal GPR Profile

FLEX NX2500 MHz
Reinforced Concrete Column — Cross-Polarisation to Image the Far Face and Calibrate Permittivity
Concrete / Civil Eng.

Reinforced Concrete Column — Cross-Polarisation to Image the Far Face and Calibrate Permittivity

FLEX NX;NX252500 MHz
Beam-and-Block Floor — Cross-Polarisation on Inline and Cross-Line Channels
Concrete / Civil Eng.

Beam-and-Block Floor — Cross-Polarisation on Inline and Cross-Line Channels

FLEX NX2500 MHz
3D Grid on Reinforced Concrete — Rebar Mesh and Diagonal Electrical Cable
Concrete / Civil Eng.Underground Utilities

3D Grid on Reinforced Concrete — Rebar Mesh and Diagonal Electrical Cable

StructureScan Mini XT/LXT2700 MHz
3D Grid on Reinforced Concrete — Welded Mesh Overlap for Rebar Picking
Concrete / Civil Eng.

3D Grid on Reinforced Concrete — Welded Mesh Overlap for Rebar Picking

NX252500 MHz
3D Grid on Densely Reinforced Concrete — Rebar Picking and C-Scan Tuning
Concrete / Civil Eng.

3D Grid on Densely Reinforced Concrete — Rebar Picking and C-Scan Tuning

StructureScan Mini XT/LXT2700 MHz
Reinforced Concrete Slab with Expansion Joint
Concrete / Civil Eng.

Reinforced Concrete Slab with Expansion Joint

FLEX NX2500 MHz
Thickness detection above three masonry bridge arches
Concrete / Civil Eng.

Thickness detection above three masonry bridge arches

UtilityScan DF300/800 MHz
Voids in a concrete block wall
Concrete / Civil Eng.

Voids in a concrete block wall

FLEX NX2500 MHz
3D concrete scanning over a slab-access ramp interface
Concrete / Civil Eng.

3D concrete scanning over a slab-access ramp interface

StructureScan Mini XT/LXT2700 MHz
Two layers of rebars in a reinforced concrete structure (3D grid)
Concrete / Civil Eng.

Two layers of rebars in a reinforced concrete structure (3D grid)

StructureScan Mini XT/LXT2700 MHz
3D Grid  Concrete bloc wall with voids
Concrete / Civil Eng.

3D Grid Concrete bloc wall with voids

FLEX NX2500 MHz
FLEX, NX25 and NX15 reference lines (MDSLab)
Concrete / Civil Eng.

FLEX, NX25 and NX15 reference lines (MDSLab)

FLEX NX;NX25;NX152500;1500 MHz
Double layer of reinforcement and structural change (1 profile)
Concrete / Civil Eng.

Double layer of reinforcement and structural change (1 profile)

StructureScan Mini XT/LXT2700 MHz
FLEX 3D grid 60 x 60 cm (reinforced concrete beam and slab).
Concrete / Civil Eng.

FLEX 3D grid 60 x 60 cm (reinforced concrete beam and slab).

FLEX NX2500 MHz

About the data for Concrete / Civil Eng.

Ground penetrating radar is essential for reinforced concrete inspection: rebar location, void detection, slab thickness measurement. The datasets presented here cover various high-frequency antennas (2 GHz and above) suited to the fine resolution required in civil engineering.